Last edited by Tunos
Monday, May 4, 2020 | History

1 edition of Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators found in the catalog.

Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators

Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators

  • 284 Want to read
  • 27 Currently reading

Published by IEEE Standards Office .
Written in English

    Subjects:
  • General,
  • Technology,
  • Technology & Industrial Arts

  • The Physical Object
    FormatPaperback
    ID Numbers
    Open LibraryOL10605182M
    ISBN 100738118346
    ISBN 109780738118345

    Power transformers – Part Standard requirements, terminology, and test code for step-voltage regulators This standard describes electrical and mechanical requirements of liquid-immersed, single- and threephase, step-voltage regulators, not exceeding a regulation of . IEC describes electrical, mechanical and test requirements of liquid-immersed, single- and three-phase, 50 Hz and 60 Hz, self and forced-air cooled, distribution, overhead and substation, step-voltage regulators, 1 kVA (single-phase units) or 3 kVA (three-phase units) and smaller, 34 volts and below (2 V minimum) and their associated controls.

    The national standard for Voltage Regulators is IEEE C which was issued by IEC as a dual logo standard - IEC Power Transformers- Standard requirements,terminology, and test code for step voltage Regulators-in These are auto-transformers with a shunt winding and full series winding as tapped winding. IEEE Std C (Revision of IEEE Std C) IEEE Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators Sponsor Transformers Committee of the IEEE Power Engineering Society Approved 16 September IEEE-SA Standards Board Abstract: Electrical, mechanical, and safety requirements of oil-fi lled, single- and.

    Adoption of IEEE Std C Description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided. Methods for performing routine and design tests applicable to liquid-immersed single and three-phase step-voltage regulators are described. Winding resistance measurements, polarity tests, insulation power factor and. This paper will apply a model of the step voltage regulator. The IEEE 13 Node Test Feeders will be used to demonstrate how the regulator is controlled in order to maintain the desired voltage for Author: William H. Kersting.


Share this book
You might also like
Hungary and the Anglo-Saxon world

Hungary and the Anglo-Saxon world

Hepatitis B & pregnancy

Hepatitis B & pregnancy

The sisters

The sisters

Landscape towards 2000, conservation or desolation

Landscape towards 2000, conservation or desolation

Large Pop-Up Books - Planes, Trains & Autos

Large Pop-Up Books - Planes, Trains & Autos

Home words for heart and hearth

Home words for heart and hearth

Architecture & construction management in the highland and remote areas of Nepal

Architecture & construction management in the highland and remote areas of Nepal

Fifteenth report on Air India--commercial & staff matters, Ministry of Tourism & Civil Aviation

Fifteenth report on Air India--commercial & staff matters, Ministry of Tourism & Civil Aviation

Yorkshire suburb

Yorkshire suburb

Spenser and the numbers of time.

Spenser and the numbers of time.

Rome is the world.

Rome is the world.

Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators Download PDF EPUB FB2

C - IEEE Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators Description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided.

Scope: This standard describes electrical and mechanical requirements of liquid-immersed, single- and three-phase, step-voltage regulators, not exceeding a regulation of kVA (for three-phase units) or kVA (for single-phase units). This standard does not apply to load tap-changing power transformers.

Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators In this paper, description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided.

IEC describes electrical, mechanical and test requirements of liquid-immersed, single- and three-phase, 50 Hz and 60 Hz, self and forced-air cooled, distribution, overhead and substation, step-voltage regulators, 1 kVA (single-phase units) or 3 kVA (three-phase units) and smaller, 34 volts and below (2 V minimum) and their associated controls.5/5(1).

IEEE standards kVA IEEE Standard IEEE standard requirements terminology test code step-voltage regulators safety requirements mechanical requirements electrical requirements oil-filled voltage regulators three-phase voltage regulators single-phase voltage regulators three-phase units single-phase units kVA.

buy iec power transformers - part standard requirements, terminology, and test code for step-voltage regulators from sai global. Browse Journals & Magazines > C - IEEE Standard Re C - IEEE Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators Add Title.

Applicable Standards The step voltage regulators shall be designed, manufactured and tested in accordance with USAS C Requirements, Terminology and Test Code for Step Voltage and Induction Voltage Regulators AS Power Transformers Technical Specification for.

Switched shunt capacitors and step voltage regulators are the two most common means used for regulating voltages. This paper addresses the modeling and the application of step voltage : William H.

Kersting. In this paper, description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided.

Methods for performing routine and design tests applicable to liquid-immersed single and three-phase step-voltage regulators are described. Winding resistance measurements, polarity tests, insulation power factor and resistance tests, ratio.

This document describes electrical, mechanical and test requirements of liquid-immersed, single- and three-phase, 50 Hz and 60 Hz, self and forced-air cooled, distribution, overhead and substation, step-voltage regulators, 1 kVA (single-phase units) or 3 kVA (threephase units) and smaller, 34 volts and below (2 V minimum) and their associated controls.

Revision Standard - Active. Description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided. Methods for performing routine and design tests applicable to liquid-immersed single and three-phase step-voltage regulators are described.

Winding resistance measurements, polarity tests, insulation power factor and. Power transformers - Part Standard requirements, terminology, and test code for step-voltage regulators About the IEC The International Electrotechnical Commission (IEC) is the world’s leading organization that prepares and publishes International Standards for all.

power transformers - part standard requirements, terminology, and test code for step-voltage regulators: iec ts power transformers - part design and application of liquid-immersed power transformers using high-temperature insulation materials: iec 1ed Power transformers.

Standard requirements, terminology, and test code for step-voltage regulators BS IEC Power transformers. Standard requirements, terminology, and test code for step-voltage regulators BS EN Power transformers. Measurement of frequency response.

IEEE Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators IEEE Std C, Electrical, mechanical, and safety requirements of oil-filled, single- and three-phase voltage regulators not exceeding regulation of kVA (for three-phase units) or kVA (for single-phase units) are covered.

Power transformers - Part Standard requirements, terminology, and test code for step-voltage regulators. This document has been re-assessed by the committee, and judged to still be up to date.

IEC describes electrical, mechanical and test requirements of liquid-immersed, single- and three-phase, 50 Hz and 60 Hz, self and. American National Standard requirements, terminology, and test code for step-voltage and induction-voltage regulators Responsibility: sponsor, Transformers Committee of the IEEE Power Engineering Society.

power transformers - part standard requirements, terminology, and test code for step-voltage regulators. Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators This document describes electrical, mechanical and test requirements of liquid-immersed, single- and three-phase, 50 Hz and 60 Hz, self and forced-air cooled, distribution, overhead and substation, IEEE C Decem.

IEEE/IEC International Standard- Power transformers - Part Standard requirements, terminology, and test code for step-voltage regulators. standard by IEEE/IEC, 12/10/ View all product details.Get this from a library! IEEE standard requirements, terminology, and test code for step-voltage regulators.

[Institute of Electrical and Electronics Engineers.; IEEE Power Engineering Society. Transformers Committee.; IEEE-SA Standards Board.;] -- Abstract: Description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided.Scope.

Applicability. This code is a safety code that shall apply to the installation of fuel gas piping systems, appliances, equipment, and related accessories as shown in (A) through (D).

(A)* Coverage of piping systems shall extend from the point of delivery to the appliance connections. For other than undiluted liquefied petroleum gas (LP-Gas) systems, the.